Gas sensors
to make your life more safe!© |
ALCOHOL DETECTOR |
|
|
|
|
|
Alcohol Detector - Ethanol |
SCM130A
 |
Characteristics
Stability for long
work periods
A wide detection
scope
Long Life
Low cost drive
circuit
|
Application
Gas leakage detecting
equipment
Alcohol detection
Dimensions.


General
Specifications.
Work parameters
|
Symbol |
Description
|
Operating Value |
Remarks |
|
VC |
Input Voltage |
5 V |
either AC or DC |
|
V |
Heating Voltage |
5 V |
either AC or DC |
|
RL |
Load resistance |
100 KOhms |
Adjustable |
|
RH |
Heater resistance |
33 Ohms +/- 5% |
at room
temperature |
|
P |
Power Consumption |
Less than 800 Mw. |
|
Environmental
operating and storage condition
|
Symbol |
Description |
Operating
Value |
Remarks |
|
Tao |
Operation
temperature |
20°C to
50 °C |
|
|
Tas |
Storage
Temperature |
20°C to
70 °C |
|
RH |
Relative humidity |
Less than 95% Rh |
|
O2 |
Oxygen
concentration |
21% (at standard
conditions) |
minimum value is
above 2% |
Sensibility
characteristics
|
Symbol |
Description |
Operating Value |
Remarks |
|
Rs |
Sensor resistance |
100 KΩ - 500 KΩ
(1000 ppm Alcohol) |
Detection ranges:
50 – 1000 ppm |
|
Standard
Detection
Conditions |
Temp. 20 °C ± 2 °C,
Vc. 5V ± 0.1
Humidity 65% ± 5% Vh.
5V ± 0.1 |
|
Preheating time (after
storage)
|
Greater than 24 Hours |
RS/ RL= (RS- VRL)/(
VRL)
Sensibility
characteristic curves for the SCM130
|
 |
Relationship
between R0/Rs and the gas concentration. |
 |
Relationship
between Voltage and the gas concentration.
The curves were
characterized at the following conditions::
Temperature, 20
°C, Humidity, 65%, Oxygen concentration, 21%, RL= 100 KOhms. Rs
is the sensing element resistance value in clean air. |
|
 |
Relationship
between surface resistance at different environment humidity. Rs
is the surface resistance at 20°C and 0% of relative humidity. |
Electric parameters of the measurement circuit

The standard test
circuit for the SCM130.
As environment
temperature and humidity have certain effect to sensitivity.
So, must consider
environment factor when accurately measuring.
 |
Shows the
relationship R0/Rs with the temperature and the humidity. |
Sensitivity
adjustment.
Resistance value
changing of SCM130 will be cause by different pieces and gas
concentration. So, when using the component, sensitivity adjustment
is necessary.
We suggest that use
100-300ppm of alcohol concentration to run the adjustment procedure.
Adjustment steps:
1. Input gas to
application circuits.
2. After storage
please pre-heating sensor over 24 hours in order to guarantee sensor
can reach stability completely.
3. In the detecting
gas concentration, adjust load resistance RL until suitable output
signal coming out.
Code: SCM130A
|
|
|
|
|
Please
read carefully the terms and conditions concerning the use of application
notes, materials, and information on this site.
Copyright © 2007 SCM International. All rights reserved.Todos los derechos reservados.
SCM International, Inc.
Mailing Address:
SCM International, Inc.
2648 E. Workman Ave. suite 527
West Covina, CA 91791
USA
Fax: +1 (530)3256895
Corporate Headquarters POBOX:
SCM International, Inc.
POBOX 9793
Reno, NV . 89507
USA
SCMStore.com, license and Conditions of use |
SCM International, Inc.
license the user to use this application by the term of a session, only under the
following terms and conditions:
|
(c)
2008, SCM International, Inc. All right reserved.
|
standard, CM100-0, cm100,
cm100-70, cm1000, cm1000-70, miniatura, cm1320, cm1360, cm1600, bajo costo
cilindricos, LTC20400, LTC20500, LTC20700, LTC20800, LTC20900, RBS020400,
RBS020500, RBS020700, RBS020800, RBS020900, RBS020600, LTC20600, RBS050100,
RBS050200 , RBS060100, LTC50100, LTC50200 , LTC60100, libre de mercurio plastico,
RBS040100, RBS090100, LCPT40100, LCPT90100, LCPT40200, LCPT70400, LCPT70300,
RBS040200, RBS070400, RBS070300, moldeados, TSM40, TSM10, TSW30, s1039,
cm1000-70, cm100-70, cm1320-70, cm2000-70, cm200-70, cm210-70, cm225-70, s1016,