MiniPLC Function Blocks
Phone Connectable - Real Time Clock - Voice Warning - Networking

 

MPLR

Symbol

Pin

Description

 

TRG

Trigger the input to activate the single pulse time relay. When the leading edge of TRG comes, a pulse with a duration of T is output.

R

Reset the single-pulse time relay. When R is 1, Output Q becomes 0.

T

The assignment of the pulse duration setting is 0.01 ~ 99.99 (second, minute, hour). The time accuracy can reach 0.5 second.

Q

Every time TRG changes from 0 to 1, Q outputs a pulse with a duration of T.

Time Sequence Frame:

Note:

- When Q is 1, TRG pulse will have no effect on Output Q.

- This function is applicable to the locations where the pulse duration is required to amplify.

 

 

     